Consulting
Development of an individual, ideal data center concept - secure, efficient and economical
Analysis
An independent picture of the infrastructure as the basis for all decisions
Strategy
With the help of our strategy modules, we support you in aligning your IT and identify and evaluate the most important influencing factors - tailored to all current and future requirements
Project Development
We check the general conditions, keep an eye on norms and standards and develop a concept - including all necessary documents
Energy and Environmental Management
We uncover weak points and potentials in the area of energy consumption and demand, tap subsidies and accompany you through audits and certifications - all the way to the implementation of an energy management system
Documentation and Manuals
Analysis and documentation of the current and target state of your IT infrastructure in the area of documentation management, structures, procedures and processes to reduce corporate and liability risks for management and IT leadership
Certification Support
Whether it is an environmental quality mark, certification as a prerequisite for customer acquisition or a requirement from your insurer - we accompany you through the process right from the start
Certification Support
Whether it is an environmental quality mark, certification as a prerequisite for customer acquisition or a requirement from your insurer - we accompany you through the process right from the start
Location criteria for data centers
Choosing the right location for the secure and reliable operation of a data center
Engineering
We plan your data center completely from one source - independent of industry, infrastructure, location and new or model construction
Architecture
We plan sustainable architecture for your project
Technical building equipment (TGA)
The correct design and optimization of technical systems contributes to maximum energy efficiency with the professional planning of technical building equipment
Technical building equipment (TGA)
The correct design and optimization of technical systems contributes to maximum energy efficiency with the professional planning of technical building equipment
Construction
We take care of the realization of data centers and the protection of your IT infrastructures, tailored to your individual needs
General contractor
You have the plan, we carry it out - right through to turnkey handover
General transferee
Everything from a single source - complete and reliable implementation of your project
Retrofitting
Optimize now to be future-proof tomorrow
Brownfield
More space for your requirements – adaptation and expansion of existing data centers
Greenfield
Greenfield data center construction
We offer high security products for your IT infrastructure
Service
We take care of the maintenance, security and economic optimization of your IT infrastructures
Maintenance
Maintenance of existing and new equipment - reduction of possible malfunctions and failures, maintenance and checking of maintenance and service protocols, possible repair work
Preventive measures
We prevent possible weak points and uncover sources of error so that we can ensure the smooth operation of your data center
Controlling and Monitoring
Round-the-clock monitoring, 24-hour hotline exclusively for contract customers, and service level agreement (SLA)
Operating costs and energy optimization
We analyze your current situation and optimize the set screws of operating and energy costs to ensure the profitability and sustainability of your data center
Cold supply
- Data Center Group
- Construction
- Cold supply
Cooling in the data center
Reliable cooling is crucial for the availability, performance, and cost-effectiveness of a data center. A comprehensive cooling strategy consists of several coordinated levels: Heat is absorbed at the IT equipment, transported out of the data center, and then dissipated into the environment or reused.
Cooling concepts differ based on how close to the heat source the cooling takes place, ranging from the entire IT room down to the individual chip. Direct evaporation, chilled water systems, and free cooling, on the other hand, form the technical infrastructure in the background and can be combined with various cooling concepts.

Cooling solutions
From traditional room cooling to direct liquid cooling: Different approaches are suitable for different power densities, rack configurations, and IT requirements, and can be combined as needed.
Technical cooling supply
The technical infrastructure determines how efficiently the absorbed heat is transported and dissipated. Technologies used include direct evaporation, water-based systems, free cooling, and mechanical refrigeration.
FAQ - Frequently Asked Questions
The most important cooling concepts include room cooling, controlled airflow, row cooling, rack cooling, and direct liquid cooling. They differ primarily in how close the cooling is located to the IT equipment or the heat source. In practice, several of these concepts are often combined.
The cooling concept describes where heat is absorbed—for example, in the room, in the rack row, at the rack, or directly from processors and GPUs. The cooling supply, on the other hand, determines how the heat is transported and dissipated. This includes, among other things, direct evaporation, water-based systems, free cooling, and chillers.
Room cooling is particularly well-suited for traditional server, storage, and network infrastructures with relatively evenly distributed heat loads. Central air conditioning or recirculating air cooling units cool the heated room air and return it to the server racks. When rack power loads vary significantly or are very high, supplemental row, rack, or liquid cooling systems may be advisable.
Enclosures prevent cold supply air and warm server exhaust air from mixing uncontrollably. As a result, the supplied cooling air is directed more precisely to the IT systems, while the warm exhaust air is removed in a controlled manner. This improves cooling performance and can reduce the data center’s energy consumption.
In row cooling, the cooling units are located within or at the end of a rack row. They specifically cool individual rows or areas with a higher heat load. In rack cooling, on the other hand, heat is removed directly from or within the server cabinet, for example, through a rear-door heat exchanger or a closed-loop rack cooling system.
In direct liquid cooling, a liquid coolant is directed directly to components that generate a particularly high amount of heat. Cold plates absorb heat directly from processors, GPUs, or accelerators. A Coolant Distribution Unit (CDU) distributes the coolant and transfers the heat to the building’s cooling circuit.
Our DC AI Container comes standard with liquid cooling.
Yes. Even in servers with direct liquid cooling, components such as memory, power supplies, and network components often continue to dissipate heat into the air. For this reason, direct liquid cooling and air cooling are combined as a hybrid cooling solution in many data centers.
Free cooling utilizes suitable outdoor conditions to dissipate heat with reduced or no active compressor operation. In direct free cooling, treated outdoor air is incorporated into the cooling process, whereas in the indirect variant, outdoor air and the data center coolant remain separate. The potential operating duration depends, among other factors, on the location, the outdoor temperature, the humidity, and the temperature level of the cooling circuit.
Do you have the right project for us?
To learn more about our Data Center design and engineering process, feel free to contact us personally. Please use our contact form or just give us a call. We look forward to hearing from you!