Consulting
Development of an individual, ideal data center concept - secure, efficient and economical
Analysis
An independent picture of the infrastructure as the basis for all decisions
Strategy
With the help of our strategy modules, we support you in aligning your IT and identify and evaluate the most important influencing factors - tailored to all current and future requirements
Project Development
We check the general conditions, keep an eye on norms and standards and develop a concept - including all necessary documents
Energy and Environmental Management
We uncover weak points and potentials in the area of energy consumption and demand, tap subsidies and accompany you through audits and certifications - all the way to the implementation of an energy management system
Documentation and Manuals
Analysis and documentation of the current and target state of your IT infrastructure in the area of documentation management, structures, procedures and processes to reduce corporate and liability risks for management and IT leadership
Certification Support
Whether it is an environmental quality mark, certification as a prerequisite for customer acquisition or a requirement from your insurer - we accompany you through the process right from the start
Certification Support
Whether it is an environmental quality mark, certification as a prerequisite for customer acquisition or a requirement from your insurer - we accompany you through the process right from the start
Location criteria for data centers
Choosing the right location for the secure and reliable operation of a data center
Engineering
We plan your data center completely from one source - independent of industry, infrastructure, location and new or model construction
Architecture
We plan sustainable architecture for your project
Technical building equipment (TGA)
The correct design and optimization of technical systems contributes to maximum energy efficiency with the professional planning of technical building equipment
Technical building equipment (TGA)
The correct design and optimization of technical systems contributes to maximum energy efficiency with the professional planning of technical building equipment
Construction
We take care of the realization of data centers and the protection of your IT infrastructures, tailored to your individual needs
General contractor
You have the plan, we carry it out - right through to turnkey handover
General transferee
Everything from a single source - complete and reliable implementation of your project
Data Center Solutions
We offer you modern and sustainable implementation options - whether modular, plug-and-play or CO2-neutral
Brownfield
More space for your requirements – adaptation and expansion of existing data centers
Greenfield
Greenfield data center construction
Retrofitting
Optimize now to be future-proof tomorrow
We offer high security products for your IT infrastructure
Service
We take care of the maintenance, security and economic optimization of your IT infrastructures
Maintenance
Maintenance of existing and new equipment - reduction of possible malfunctions and failures, maintenance and checking of maintenance and service protocols, possible repair work
Preventive measures
We prevent possible weak points and uncover sources of error so that we can ensure the smooth operation of your data center
Controlling and Monitoring
Round-the-clock monitoring, 24-hour hotline exclusively for contract customers, and service level agreement (SLA)
Operating costs and energy optimization
We analyze your current situation and optimize the set screws of operating and energy costs to ensure the profitability and sustainability of your data center
- Data Center Group
- Products
- DC IT Container
- DC IT AI Container
DC AI Container
The modular and mobile high-performance container for the most demanding requirements, delivered in the shortest possible time.
-
High-Density Container solution
-
innovative cooling concept with Liquid Cooling
-
energy-efficient and sustainable with low power usage effectiveness (PUE)
-
high level of burglary protection
-
meets all requirements for fire protection and protection against external influences
The Container Solution for Artificial Intelligence
With the rapid growth of AI applications and high-performance computing, the demands on modern data center infrastructures—which must be deployed as quickly as possible—are also increasing. High-performance GPUs and high-density systems generate enormous amounts of heat, which can only be dissipated with limited efficiency using conventional air cooling. Traditional cooling concepts are increasingly reaching their physical and energy-related limits.
The DC AI Container therefore relies exclusively on liquid cooling—for maximum performance, efficiency, and future-proofing. Thanks to its direct and highly efficient heat dissipation, liquid cooling enables significantly higher computing densities in the smallest of spaces, reduces energy losses, and sustainably improves energy efficiency. In this way, the DC AI Container provides the ideal foundation for demanding AI workloads, GPU clusters, and modern high-performance environments.
Your advantages with the DC AI Container
Energy Efficiency and Sustainability
Liquid cooling significantly reduces energy consumption by replacing traditional air conditioning systems with more efficient ones. At the same time, the coolant is reused in a closed-loop system, and waste heat can be utilized in a sustainable manner.
Maximum performance for AI
Modern GPUs generate enormous amounts of heat that can hardly be dissipated efficiently using air cooling alone. Liquid cooling enables maximum computing power in the smallest of spaces without any loss of performance due to overheating.
Rapid provision of high computing power
DC AI Containers enable the rapid and scalable deployment of powerful AI infrastructures. In a very short time, companies can obtain custom-built, highly available, high-performance environments for demanding AI workloads.
Technical data
Optional:
- Smoke extraction system / Early fire detection
- Fire alarm control panel with fire suppression system and pressure relief valve
- Intruder alarm system with access control system
- Lightning protection system
- DC IT Shielding Container with at least 80 dB shielding attenuation and a frequency range up to 1 GHz; shielding quality tested and validated by the BSI
Functioning of liquid cooling
A heat sink sits directly on top of the processor and absorbs the heat generated through direct contact. The coolant flowing through it absorbs the heat directly from the chip.
The heated fluid is transported from the server to the central cooling unit via a closed piping system.
In the DLC unit, the coolant transfers heat to a separate water circuit via a heat exchanger.
The cooled liquid is pumped back to the servers, and the cooling process begins again.
Implementation options
| 25 kW per Rack | 50 kW per Rack | 100 kW per Rack | |
| Rack system | 1 unit 800x1200x2200, 47HE | 1 unit 800/900x1400x2200, 47HE | 1 unit 800/900x1400x2200, 47HE |
| InRack DLC unit, 6HE (water cooling) | 1 unit, standard, up to 50 kW (redundancy also available) | 1 unit, standard, up to 50 kW (redundancy also available) | 1 unit extreme up to 150 kW (redundancy also available) |
| Manifold | 2 pieces (1 supply line, 1 return line), each with a coupling | 2 pieces (1 supply line, 1 return line), each with a coupling | 2 pieces (1 supply line, 1 return line), each with a coupling |
| PDU / Power rails | in required quantity and configuration | in required quantity and configuration | in required quantity and configuration |
| Side cooler (air-cooled) – Customizable CW (chilled water) or DX (direct expansion) (approx. 20% of the container's total capacity) | in required quantity and configuration | in required quantity and configuration | in required quantity and configuration |
| Outdoor unit (air-cooled) – available in CW (chilled water) or DX (direct expansion) configurations | in required quantity and configuration | in required quantity and configuration | in required quantity and configuration |
| Open-circuit cooler (hot water cooling, water) | in required quantity and configuration | in required quantity and configuration | in required quantity and configuration |
| Water treatment | optional | optional | optional |
Full protection against physical hazards
Fire protection
Specialized fire protection for your IT Systems in accordance with DIN EN 1047-2
Burglary protection
Protect your IT infrastructure against break-ins or unauthorized access in accordance with EN 1627
Explosion protection
In accordance with EN 13123-2 / 13124-2 – so your IT stays up and running even in the worst-case scenario.
Water and dust protection
Water and dust protection in accordance with EN 60529 to protect hardware and data.
Protection against falling debris
Even if the building's structural elements collapse, your IT systems will remain protected.
Protection against vandalism
Protect your IT infrastructure against vandalism.
Protection against radiation
Optimal protection against eavesdropping and electromagnetic radiation.
Noise control
Reduce the noise level in your server room.
Protection against corrosive gases
Prevent corrosion damage.
More information about the modular DC IT container
The DC AI Container offers all the benefits and protective features of the DC IT Container, combined with sustainable cooling designed specifically for high power densities
Downloads
What can we do for you?
Together we will find the right products and services for your individual needs. To learn more, please feel free to contact us personally. To do so, use our contact form or simply give us a call. We look forward to hearing from you!