DC IT Shielding Room
Shielding for server rooms
- Protection against electromagnetic interference
- Modular room-in-room system consisting of wall, ceiling and floor elements
- Structural IT protection in accordance with recognized data center standards; depending on the design, in accordance with BITKOM, BSI, and EN 50600
- Extended basic protection for IT against the main physical hazards (fire, burglary, water, dust, EMC electromagnetic compatibility...)
- System-tested fire protection with various protection options depending on the model
- Burglary protection starting at RC 2; depending on the model, optional higher burglary resistance is available
Shielded server rooms for sensitive IT infrastructures
Perfect protection against electromagnetic influences
Data theft
Espionage attacks
(e.g., industrial espionage and intelligence services)
Electronic Attacks
Technical eavesdropping attacks
Natural electromagnetic peaks
(e.g., lightning strikes)
Drone attacks
using GPS or radio jammers
Non-nuclear electromagnetic pulse / high-power microwave attacks
(NNEMP/HPM)
Compromising emanations
(unintentional information leakage)
Benefits of IT Room Shielding
Comprehensive protection for your entire IT infrastructure
The entire server room is designed as a closed, secure environment.
Customization to fit buildings and infrastructure
The design can be precisely adapted to existing buildings and technical requirements.
Reduced maintenance requirements
Neither the shielded room, nor the filter systems, nor any other components require regular maintenance; only the door needs to be serviced once a year. This significantly reduces both effort and operating costs.
Construction of shielded rooms
Our shielded rooms are constructed from metal panels that are joined together to form a closed structure.
We use galvanized steel panels with a thickness of approximately two millimeters, as these provide high stability and reliable protection.
Depending on the project requirements, the structure can be assembled using a modular design or welded directly together.

Technical Implementation of Room Shielding
The metal structure of a room-in-room data center forms the basis for a closed electromagnetic shielding enclosure. This creates a fully shielded IT area within existing buildings, reliably protecting sensitive systems from electromagnetic interference and unwanted radiation.
The shielding is provided by a continuously conductive room structure made of high-quality, galvanized steel panels approximately two millimeters thick. This construction combines high mechanical stability with effective shielding across a broad frequency spectrum.
Special attention is paid to the implementation of all openings and interfaces. Doors, ventilation elements, and media and cable penetrations are technically controlled and integrated, and conductively incorporated into the shielding structure. Only the precise interaction of all components ensures a permanently closed Faraday structure and thus reliable electromagnetic shielding.
Depending on project requirements, DC IT Shielding for room-in-room data centers can be implemented in various configurations.
Steel sheet cabin
- Shielding cabins made of 2 mm galvanized steel form a closed Faraday structure and reliably protect against electromagnetic radiation across high frequency ranges
- Prefabricated steel modules allow the cabin to be installed quickly and adapted or expanded to meet individual room and project requirements
- Corrosion-protected steel sheets and precisely manufactured connection systems ensure high stability, long-term tightness, and reliable operation in daily use
Copper foil

- Copper foil with a thickness of 0.2–0.3 mm achieves shielding attenuation of >100 dB in the frequency range from 30 MHz to 10 GHz.
- Continuous, lead-free soft soldering creates a closed and particularly dense shielding enclosure.
- The tightly soldered copper construction simultaneously acts as a reliable vapor barrier from a building physics perspective.
Verified shielding performance

- System tested shielding effectiveness according to EN 50147-1, NSA 65-6, IEEE-STD 299 (MIL-STD 285)
- Certified according to ISO 9001 and ISO 14001
- High-availability protection with emission and immunity protection >80 dB. Radiation from IT equipment is reduced by a factor of 10,000
- Compliant with BSI requirements (German Federal Office for Information Security)
- Meets NATO-(SDIP-29) and TEMPEST requirements
- Patented shielding doors and gates (airlocks)
Unser Schutzschirm für jedes Produkt
DC IT Shielding Configurator
Your sensitive IT systems deserve more than just standard protection. Configure your custom shielding solution now to protect against electromagnetic interference, data leakage, and external disturbances – tailored specifically to your infrastructure. DC IT Shielding – proven security for highly sensitive IT environments.







![[Translate to English:] Wandelement eines geschirmten Rechenzentrums](/fileadmin/_processed_/e/6/csm_DSC01365_b5906d152c.jpg)