Simply configure your DC ITContainer yourself. After sending the configuration, you will immediately receive a suitable offer from us. If you have questions, we are happy to help.
In times of extremly growing amounts of data, you often face a lack of space in IT environments. Our solution is the modular DC-IT Container. Available in a 20 ft or 40 ft design, the ISO (or non ISO!) container is constructed to withstand even the hardest strains. The robust and entirely welded container construction qualifies as a durable solution, e. g. in industrial production halls or out in the open. It withstands everything. It also qualifies as an interim solution that can be transported easily and is therefore always flexible and mobile.
Moreover, the DC-IT Container is a plug & play solution: Quickly connected to the power supply after the delivery, it is instantly in running order. Hence, the time between order and initial operation is significantly shorter than for a conventional data center. On top of that, the process is much cleaner: there are no adjustments necessary on site - there just needs to be enough space and concrete slab for the respective statics of the container.
The DC-IT Container is also suitable for the setup of edge IT infrastructures, e. g. at production sites, along motorway networks, fiber networks... Why? Because the demand for turnkey ready data center solutions, that are modular, secure and high-available, keeps on growing, especially in times of digitalization and growing automation. Consequently, they can be realized flexibly and in a timely manner. In some cases the DC-IT Containerized datacenter solution is a perfect backup solution to your existing IT room.
Technical Information | DC-ITContainer ITC 20 | DC-ITContainer ITC 40 | DC-ITContainer Granite 20 and 40 |
---|---|---|---|
Length (external/internal) | 6.058 / 5.420 mm | 12.192 / 11.550 mm | 6.058 / 5.330 mm or 12.192 / 11.460 mm |
Width (external/internal) | 2.438 / 2.140 mm | 2.438 / 2.140 mm | 2.438 / 2.040 mm |
Height (external/internal) | 2.896 / 2.550 mm | 2.896 / 2.550 mm | 2.896 / 2.440 mm |
Amount 482,6 mm (19") racks, 43 HU, 600 x 1000 mm WxD (racks for IT, technology, cooling) | max. 6 | max. 16 | max. 16 |
Cooling (100 % redundant) | 2 front coolers | 2-4 front coolers | 2 or 2-4 front coolers |
UPS | ✔ | ✔ | ✔ |
Early Fire Detection/ Extinguishing System | ✔ | ✔ | ✔ |
Hot Aisle Containment | ✔ | ✔ | ✔ |
Electrical Subdistribution Unit | ✔ | ✔ | ✔ |
Floor | Plafond floor (raised floor optional) | Plafond floor (raised floor optional) | Plafond floor (raised floor optional) |
Excess Pressure Flap (pneumatic) | ✔ | ✔ | ✔ |
Protective Features | |||
Fire Protection | EI90/F90 | EI90/F90 | R60D acc. to EN 1047-2 and EI180/F180 |
Anti-Burglary Protection | RC 3 (RC 4 optional) | RC 3 ( RC 4 optional) | RC 3 (RC 4 optional) |
Dust Protection IP 56 acc. to EN 60529 | ✔ | ✔ | ✔ |
Protection from Extinguishing Water IP 56 acc. to EN 50629 | ✔ | ✔ | ✔ |
Flue Gas Imperviousness acc. to EN 1634-3 | ✔ | ✔ | ✔ |
DC-ITContainer 20ft HC
High-Cube ISO-Container
Technical Features | DC-ITContainer 20ft HC |
---|---|
Length (external/internal) | 6.058 / 5.420 mm |
Width (external/internal) | 2.438 / 2.140 mm |
Height (external/internal) | 2.896 / 2.550 mm |
Fire Resistant Cladding | F90 Fire Resistant Cladding |
Emergency Fire Door | T90 Emergency Fire Door (implemented) with smoke protection |
Fire Wall Systems | Modular - Pneumatic Excess Pressure Flap with Weather Protection Grid for Linking an Extinguishing System |
Flooring | Plafond floor |
Physical Protection | |
---|---|
EI90 | Certified acc. to EN 1363-1 and EN 13501-2 |
Anti-Burglary Protection | Certified RC2, optional RC 3 or RC 4 |
Resistance against Debris Load | ✔ |
Dust Protection | IP 56 acc. to EN 60529 |
Protection from Extinguishing Water | IP 56 acc. to EN 60529, Driving Rain Imperviousness |
Flue Gas Imperviousness | acc. to EN 1634-3 |
Noise Protection | ✔ |
Explosion Protection | ✔ |
EMC Protection | ✔ |
DC-ITContainer 40ft HC
High-Cube ISO-Container
Technical Features | DC-ITContainer 40ft HC |
---|---|
Length (external/internal) | 12.192 / 11.550 mm |
Width (external/internal) | 2.438 / 2.140 mm |
Height (external/internal) | 2.896 / 2.550 mm |
Fire Resistant Cladding | F90 Fire Resistant Cladding |
Emergency Fire Door | T90 Emergency Fire Door (implemented) with smoke protection |
Fire Wall Systems | Modular - Pneumatic Excess Pressure Flap with Weather Protection Grid for Linking an Extinguishing System |
Flooring | Plafond floor |
Physical Protection | |
---|---|
EI90 | Certified acc. to EN 1363-1 and EN 13501-2 |
Anti-Burglary Protection | Certified RC2, optional RC 3 or RC 4 |
Resistance against Debris Load | ✔ |
Dust Protection | IP 56 acc. to EN 60529 |
Protection from Extinguishing Water | IP 56 acc. to EN 60529, Driving Rain Imperviousness |
Flue Gas Imperviousness | acc. to EN 1634-3 |
Noise Protection | ✔ |
Explosion Protection | ✔ |
EMC Protection | ✔ |
DC-ITContainer GranITe 20ft HC
High-Cube ISO-Container
Technical Features | DC-ITContainer GranITe 20ft HC |
---|---|
Length (external/internal) | 6.058 / 5.420 mm |
Width (external/internal) | 2.438 / 2.140 mm |
Height (external/internal) | 2.896 / 2.550 mm |
Fire Resistant Cladding | R60D acc. to EN 1047-2 and EI180/F180 |
Emergency Fire Door | T90 Emergency Fire Door (implemented) with smoke protection |
Fire Wall Systems | Modular - Pneumatic Excess Pressure Flap with Weather Protection Grid for Linking an Extinguishing System |
Flooring | Plafond floor |
Physical Protection | |
---|---|
ECB-S | Certification and Type Test acc. to EN 1047-2 |
EI90 | System-Tested from Inside and Outside acc. to EN 1363-1 und EN 13501-2 |
EI120 | Certified Inside acc. to EN 1363-1 und EN 13501-2 |
EI180 | Certified Outside acc. to EN 1363-1 und EN 13501-2 |
Anti-Burglary Protection | min. RC3 certified acc. to EN 1627 / EN 1628 EN 1629 / EN 1630 |
Resistance against Debris Load | Shock Test acc. to EN 1047-2 |
Dust Protection | IP 56 acc. to EN 60529 |
Protection from Extinguishing Water | IP 56 acc. to EN 60529, Protection from Ponding Water |
Flue Gas Imperviousness | acc. to EN 1634-3 |
Noise Protection | acc. to DIN 4109, DIN EN ISO 354, 140 and 717 |
Explosion Protection | EXR 3 acc. to EN 13123-2/13124-2 |
EMC Protection | acc. to EN 50147 |
One fire protection is not like the other. There are special requirements for the IT!
Protect your IT-infrastructure from burglary or unauthorized access.
So your IT stays intact in the worst-case scenario
Your IT is protected in case the primary building elements cave in.
Protect your IT-infrastructure from willful destruction and vandalism.
Water and dust protection according to EN 60529 for the protection of hardware and data.
Ideal protection from eavesdropping operations and electromagnetic emission.
Reduce the acoustic level of your server room.
Protect your IT from corrosive gases.
UPS-Systems
UPS systems are used wherever you cannot afford any downtimes. In case of a blackout, the UPS solution takes over the operation in order to prevent loss of data or damage to the IT. Modern UPS systems are equipped with a double conversion online topology that aims for an accurate voltage and frequency regulation, an absolutely uninterrupted shift between mains supply and battery supply as well as a performance factor adjustment.
Power Distribution Unit (PDU)
Power Distribution Units do a lot more than "just" bring the power to the terminal device. Our intelligent and active PDU systems have several control panels and can control specific outlets separately. They can also turn them all on or off at the same time, e. g. if there were any rules made and the determined conditions apply. There are also a lot of safety features within the intelligent PDUs, like the integration of safety logs, which prevent unauthorized access, or alarm signals that are sent if a predefined safety limit is exceeded or undershot at a performance measurement.
DC-MonIToring - DCM Agent
The DCM Agent is an indispensable part of the DC-ITContainer because it offers countless options in the smallest spaces: It reads and collects the functional and operational information data of the entire IT inside the data center at the respective measuring points. It compares and assesses the actual figures with the set values through predefined features. If incorrect temperatures, too much humidity, water inlet, fire, smoke or motion detection as well as abnormalities with the access control or the power surveillance appear, the DCM Agent will send fault reports via e-mail or SMS to you or to the Network Operation Center (NOC).
For better access, the racks are positioned on these premium and steady telescopic rails that can be moved. In order to guarantee optimal security and maximal availability even in an extended state, the cables are put into specific routings that move along with the telescopic rails.
Energy Efficient Cooling
The temperature of your data center plays an important role in the running operation. It is good if the temperature can be kept at a reliably low level. But it is even better if the entire procedure is also energy efficient. The separation of hot and cold aisles within the DC-ITContainer is just the beginning.
One fire protection is not like the other. There are special requirements for the IT!
Protect your IT-infrastructure from burglary or unauthorized access.
So your IT stays intact in the worst-case scenario
Your IT is protected in case the primary building elements cave in.
Protect your IT-infrastructure from willful destruction and vandalism.
Water and dust protection according to EN 60529 for the protection of hardware and data.
Ideal protection from eavesdropping operations and electromagnetic emission.
Reduce the acoustic level of your server room.
Protect your IT from corrosive gases.
Your IT requires particularly high-quality protection. No company can afford to leave its data unprotected, neither digitally nor physically. That is why RZproducts, as part of the DATA CENTER GROUP, has been developing innovative protection systems for IT infrastructure since 2008. Our products are certified and quality checked. Independent, globally recognized bodies guarantee our product quality. Products like the GranITe IT room have successfully passed the most stringent and demanding security and quality tests.
As a subsidiary of DC-Datacenter-Group GmbH, RZ-Products GmbH specializes in the development, production and marketing of high-quality IT security products that are used in companies worldwide. We offer innovative solutions for the security equipment of data centers. Our products are "Made in Germany" produced in Wallmenroth in the Westerwald.