DC IT Container
Customized

Mobile, modular, robust and absolutely reliable

  • Fully welded steel container
  • Fire protection: EI90, EI60, EI30 (i -> o) according to EN 13501-2 and EN 1363-1
  • Dust and water tightness IP 56 according to EN 60529
  • Flue gas tightness according to EN 1634-3
  • Burglary protection RC 3-4 according to EN 1627/EN1630
  • Corrosion protection system for ambient conditions C1 (indoor) to C5 (coastal) according to DIN EN ISO 12944
Configure now

Close-ups DC IT Container

floor open with cable
Iron struts
DC IT Container Monitoring System
safety system and fire extinguisher
Safety system open
Two Link DC IT Container Black
server aisle and server cabinets
Ceiling of the container with cables and connections and emergency exit shield
entrance to the container closed
entrance to the container open
server aisle and cabinets
detail view rack with cables and connectors
server cabinets, security door and fire extinguisher

Protected against physical hazards

Fire protection

Fire protection: EI90, EI60, EI30 (i -> o) according to EN 13501-2 and EN 1363-1

Burglary protection

Protect your IT infrastructure from intrusion or unauthorized third-party access according to EN1627

Explosion protection

According to EN 13123-2 / 13124-2 - so that your IT remains intact even in the worst case scenario.

Water and dust protection

Water and dust protection according to EN 60529 to protect hardware and data.

Protection from debris load

Should the load-bearing building elements collapse, your IT remains protected.

Protection against vandalism

Protect your IT infrastructure against wanton destruction.

mobile-data
Protection from radiation

Optimal protection against eavesdropping and electromagnetic radiation.

hearing
Noise protection

Lower the noise level of your server room.

Protection against corrosive gases

Prevent corrosive destruction.

Properly equipped for every purpose

The DC IT container has appropriate protection values, which can be designed individually. Inside the container data center are the IT rack systems and the associated technology. Optionally, the container can be equipped with a partition wall inside to create a separation between the server and technical areas. The DC IT Container is designed as a customer-specific all-in-one solution and handed over ready for operation.

DC IT Container Grafik

Equipment options

 

600mm width
800mm width
1000mm depth
1200mm depth
2000mm height, 43u
2200mm height, 47u

 

Individual cold or hot containment, customized to the number of racks and cooling units.

Cooling with refrigerant R410a or R32
Side cooler with outdoor unit, ca. 5kW (possible with or without redundancy)
Side cooler with outdoor unit, ca. 10kW (possible with or without redundancy)
Side cooler with outdoor unit, ca. 15kW (possible with or without redundancy)
Side cooler with outdoor unit, ca. 20kW (possible with or without redundancy)
Side cooler with outdoor unit, ca. 25kW (possible with or without redundancy)
Solutions with alternative technical options are possible at all times!

Cooling with cold water
Side cooler with cold water-cold production external unit (possible with or without redundancy, possible with or without free cooling) Solutions with alternative technical solutions are possible at all times.

A cooling solution with indirect free cooling is available

A cooling solution with direct free cooling is available

 

  • Static UPS in various power performance levels with internal or external batteries  (available with or without redundancv)   
  • Modulare UPS for an individual performance extension thanks to UPS power modules in various power performance levels with internal or external batteries (available with or without redundancy)

PDU‘s are available from the basic versions up to smart PDU’s that include Measurement and Switching Functionalities, according to customer specifications.

  • Power supply with sub-distribution, and cabling between the racks and the sub-distribution, A-Path over the UPS, B-Path over normal power.
  • Power supply with sub-distribution, and cabling between the racks and the sub-distribution. A+B paths over UPS
  • Complete turnkey electrical installation including all cable trays / mesh trays and inside lighting of the container (including emergency exit lighting).

Room - Early Fire Detection for DC-IT Container (either for server room and/or technical space)

Room - Fire Extinguishing System incl. bottle (s) of extinguishing product for the volume of the DC-IT container (either for server room and/or technical space).

DCM Agent 32DI 2 PS incl. Accessories
DCM Extension Package
Combi - sensors for temperature & air humidity for DCM Detection/Agent
Humidity Sensors
Smoke / Fire Detectors
Temperature sensors
Sensors for water leakage

Our DC IT Containers in comparison

*Note: The max. possible number of rack systems depends on the size of the rack systems (width: 600mm, 800mm), the further equipment as well as the required cooling of the container! / **Note: Deviating requirements possible on request!
  DC IT Container ISO 20ft HC DC IT Container ISO 40ft HC DC IT Container Customized
EQUIPMENT FEATURES      
External dimensions (LxWxH) 6,058 x 2,438 x 2,896 mm 12,192 x 2,438 x 2,896 mm Individual according to project requirement
Number of rack systems* Approx. 5-6 (base 600mm wide racks) Approx. 14-15 (base 600mm wide racks) Individual according to project requirement
Dissipative flooring or raised floor
Hot or cold aisle containment
Air conditioning with or without redundancy by means of refrigerant, chilled water, indirect free cooling or direct free cooling
Electrical distributions in single-path or two-path (A/B) design
UPS with or without redundancy
Early fire detection and extinguishing system
PROTECTIVE PROPERTIES      
Fire protection** EI90, EI60, EI30 (i -> o) according to EN 13501-2 and EN 1363-1 EI90, EI60, EI30 (i -> o) according to EN 13501-2 and EN 1363-1 EI90, EI60, EI30 (i -> o) according to EN 13501-2 and EN 1363-1
Burglary protection RC4 (on request), RC3, RC2 according to EN 1627/EN 1630 RC4 (on request), RC3, RC2 according to EN 1627/EN 1630 RC4 (on request), RC3, RC2 according to EN 1627/EN 1630
Dust and waterproof IP 56 according to EN60529 IP 56 according to EN60529 IP 56 according to EN60529
Flue gas tightness According to EN 1634-3 According to EN 1634-3 According to EN 1634-3
Corrosion protection system Corrosivity category C1 (indoor) - C5 (coastal) Corrosivity category C1 (indoor) - C5 (coastal) Corrosivity category C1 (indoor) - C5 (coastal)
Climatic conditions** Outdoor temperatures from approx. -20°C / -4°F to approx. +40°C / +104°F Outdoor temperatures from approx. -20°C / -4°F to approx. +40°C / +104°F Outdoor temperatures from approx. -20°C / -4°F to approx. +40°C / +104°F
Soil load** 500 kg/m² 500 kg/m² 500 kg/m²
Roof load** 150 kg/m² 150 kg/m² 150 kg/m²
Wind load** Base wind speed vb,0= 20,0 ma-1 Base wind speed vb,0= 20,0 ma-1 Base wind speed vb,0= 20,0 ma-1

What can we do for you?

Together we will find the right products and services for your individual needs. To learn more, please feel free to contact us personally. To do so, use our contact form or simply give us a call. We look forward to hearing from you!